| General information | |
| Product type designation | DI 16x230VAC BA |
| HW functional status | FS01 |
| Firmware version ● FW update possible | V2.0.0 Yes |
| Product function | |
| ● I&M data ● Isochronous mode ● Prioritized startup | Yes; I&M0 to I&M3 No Yes |
| Engineering with | |
| ● STEP 7 TIA Portal configurable/integrated as of | V12 / V12 |
| version | |
| ● STEP 7 configurable/integrated as of version | V5.5 SP3 / – |
| ● PROFIBUS as of GSD version/GSD revision | V1.0 / V5.1 |
| ● PROFINET as of GSD version/GSD revision | V2.3 / – |
| Operating mode | |
| ● DI | Yes |
| Power | |
| Power available from the backplane bus | 1 W |
| Power loss | |
| Power loss, typ. | 4.9 W |
| Digital inputs | |
| Number of digital inputs | 16 |
| Digital inputs, parameterizable | No |
| Source/sink input | P-reading |
| Input characteristic curve in accordance with IEC 61131, type 1 | Yes |
Input voltage | |
| ● Rated value (AC) ● for signal “0” for signal “1” | 230 V; 120/230 V AC, 50/60 Hz 0V AC to 40V AC 79V AC to 264V AC |
| Input current | |
| ● for signal “1”, typ. | 11 mA; At 230 V AC and 5.5 mA at 120 V AC |
| Input delay (for rated value of input voltage) | |
| for standard inputs | |
| — parameterizable — at “0” to “1”, max. — at “1” to “0”, max. | No 25 ms 25 ms |
| for interrupt inputs | |
| — parameterizable | No |
| for technological functions | |
| — parameterizable | No |
| Cable length | |
| ● shielded, max. ● unshielded, max. | 1 000 m 600 m |
Encoder | |
| Connectable encoders | |
| ● 2-wire sensor — permissible quiescent current (2-wire sensor), max. | Yes 2 mA |
| Interrupts/diagnostics/status information | |
| Diagnostics function | No |
| Alarms | |
| ● Diagnostic alarm ● Hardware interrupt | No No |
| Diagnostic messages | |
| ● Monitoring the supply voltage ● Wire-break ● Short-circuit | No No No |
| Diagnostics indication LED | |
| ● RUN LED | Yes; green LED |
| ● ERROR LED | Yes; red LED |
| ● Monitoring of the supply voltage (PWR-LED) | No |
| ● Channel status display | Yes; green LED |
| ● for channel diagnostics | No |
| ● for module diagnostics | Yes; red LED |
| Potential separation | |
Potential separation channels | |
| ● between the channels ● between the channels, in groups of between the channels and backplane bus | No 4 Yes |
| Permissible potential difference | |
| between different circuits | 250 V AC between the channels and the backplane bus; 500 V AC between the channels |
| Isolation | |
| Isolation tested with | 3 100 V DC |
| Standards, approvals, certificates | |
| Suitable for safety functions | No |
Ambient conditions | |
| Ambient temperature during operation | |
| ● horizontal installation, min. | 0 °C |
| ● horizontal installation, max. | 60 °C |
| ● vertical installation, min. | 0 °C |
| ● vertical installation, max. | 40 °C |
| Dimensions | |
| Width | 35 mm |
| Height | 147 mm |
| Depth | 129 mm |
| Weights | |
| Weight, approx. | 300 g |