Our motor rewinding and repair service includes:
A. Motor Inspection & Testing:
Visual inspection for damage or wear.
Testing of insulation resistance and winding continuity.
Checking bearings, shafts, and housing for wear.
B. Rewinding Process:
Complete removal of existing windings.
Cleaning of stator and rotor laminations.
Rewinding with high-quality copper wire according to OEM specifications.
Insulation impregnation for durability and heat resistance.
C. Replacement & Maintenance:
Replacement of bearings and seals if required.
Balancing of rotor to prevent vibrations.
Reassembly, lubrication, and alignment.
D. Final Testing:
No-load and full-load testing.
Voltage, current, and insulation checks.
Vibration and noise assessment.